Products

Blown-in insulation supplier in Denver

Knauf Insulation blowing wool, Mountain Fiber Insulation cellulose and Intec blowing machines for attic and wall jobs.

We deliver from Denver; contractors can open a trade account.

Which fill, which job

Tap a part to see the best choice

AtticWalls

Best · Attic

Jet Stream Ultra

Fewest bags per 1,000 sq ft: 13.6 at R-30, against 15.3 for EcoFill and 42.9 for cellulose. Top-up: send us your current depth.

Get a Quote

New wall: Jet Stream Ultra fills closed cavities behind netting or Insul-OC fabric: 16.4 bags per 1,000 sq ft for R-15 in a 2x4, 25.8 for R-23 in a 2x6. Machine: use an Intec blowing machine (Force 2 with hose package or Force/2 HP) and 150 ft of 3 in. hose.

Sealing and baffles
  • ENERGY STAR advises sealing attic floor leaks before you add insulation.
  • In a vented attic, put a baffle at the soffit vents; loose-fill also needs a dam or retainer.

Bags we carry

One bag at R-30 in an open attic.

  • Jet Stream Ultra

    73.3sq ft

    Fiberglass blowing wool, 32 lb bag

  • EcoFill

    65.5sq ft

    Fiberglass blowing wool

  • Mountain Fiber Insulation cellulose

    23.3sq ft

    Cellulose, 25 lb bag, 44 to a pallet

Jet Stream Ultra bags

Bags per 1,000 sq ft of open attic, with settled thickness.

  1. R-11: 4.7, 4 in.
  2. R-13: 5.7, 4.75 in.
  3. R-19: 8.4, 6.75 in.
  4. R-22: 9.8, 7.75 in.
  5. R-26: 11.8, 9.125 in.
  6. R-30: 13.6, 10.375 in.
  7. R-38: 17.8, 13 in.
  8. R-44: 20.9, 14.875 in.
  9. R-49: 23.5, 16.375 in.
  10. R-60: 29.7, 19.75 in.

Jet Stream Ultra: Knauf Insulation data sheet. Cellulose: Mountain Fiber coverage chart in the catalog.

Cellulose bags by R-value
  • R-19: 27.2 bags per 1,000 sq ft.
  • R-38: 54.4 bags.
  • R-49: 70.1 bags.

Bag calculator

Pick the job, enter the area, and get the Jet Stream Ultra bags to order.

Enter the area.

Bags = area ÷ 1,000 × bags per 1,000 sq ft, rounded up.

Frequently asked questions

Cellulose or fiberglass blown-in: which should I order?

Either one fills open attics and dense-packs existing walls.

Should I blow the attic to R-49 or R-60?

R-60 under the 2021 energy code, R-49 under 2024. Your jurisdiction's code and permit date decide; see the code guide.

Why does thickness matter?

The R-value holds only at the label's settled thickness.

Need blown-in for a job?

Send the square footage and target R-value for a quote.

Call us:+1 (720) 502-6469

Same-day and next-day delivery on most products across the Front Range. Delivered from Denver.

Request a quote

Tell us what you need and we will reply with availability and pricing.