Which fill, which job
Tap a part to see the best choice
Best · Attic
Jet Stream Ultra
Fewest bags per 1,000 sq ft: 13.6 at R-30, against 15.3 for EcoFill and 42.9 for cellulose. Top-up: send us your current depth.
Get a QuoteBest · Walls
Dense-pack
Existing wall: dense-pack it, which means filling the wall tight, and cap the holes with 2.5 in. wood plugs.
Get a QuoteNew wall: Jet Stream Ultra fills closed cavities behind netting or Insul-OC fabric: 16.4 bags per 1,000 sq ft for R-15 in a 2x4, 25.8 for R-23 in a 2x6. Machine: use an Intec blowing machine (Force 2 with hose package or Force/2 HP) and 150 ft of 3 in. hose.
Sealing and baffles
- ENERGY STAR advises sealing attic floor leaks before you add insulation.
- In a vented attic, put a baffle at the soffit vents; loose-fill also needs a dam or retainer.
Bags we carry
One bag at R-30 in an open attic.
Jet Stream Ultra
73.3sq ft
Fiberglass blowing wool, 32 lb bag
EcoFill
65.5sq ft
Fiberglass blowing wool
Mountain Fiber Insulation cellulose
23.3sq ft
Cellulose, 25 lb bag, 44 to a pallet
Jet Stream Ultra bags
Bags per 1,000 sq ft of open attic, with settled thickness.
- R-11: 4.7, 4 in.
- R-13: 5.7, 4.75 in.
- R-19: 8.4, 6.75 in.
- R-22: 9.8, 7.75 in.
- R-26: 11.8, 9.125 in.
- R-30: 13.6, 10.375 in.
- R-38: 17.8, 13 in.
- R-44: 20.9, 14.875 in.
- R-49: 23.5, 16.375 in.
- R-60: 29.7, 19.75 in.
Jet Stream Ultra: Knauf Insulation data sheet. Cellulose: Mountain Fiber coverage chart in the catalog.
Cellulose bags by R-value
- R-19: 27.2 bags per 1,000 sq ft.
- R-38: 54.4 bags.
- R-49: 70.1 bags.
Bag calculator
Pick the job, enter the area, and get the Jet Stream Ultra bags to order.
Enter the area.
Bags = area ÷ 1,000 × bags per 1,000 sq ft, rounded up.
Frequently asked questions
Cellulose or fiberglass blown-in: which should I order?
Either one fills open attics and dense-packs existing walls.
Should I blow the attic to R-49 or R-60?
R-60 under the 2021 energy code, R-49 under 2024. Your jurisdiction's code and permit date decide; see the code guide.
Why does thickness matter?
The R-value holds only at the label's settled thickness.
Reviewed by the Pop Supply team ·
Sources (9)
- Knauf Insulation, Jet Stream Ultra product page (2026-01)
- Knauf Insulation, Jet Stream Ultra data sheet (2026-01)
- Knauf Insulation, EcoFill product page (2025-04)
- Intec, insulation blowing machines
- 2021 IECC, Colorado DFPC text, Chapter 4
- 2024 IECC, Colorado text, Chapter 4
- ENERGY STAR, Well-Insulated and Sealed Attic
- DOE Building America, blown insulation for existing walls
- DOE Building America, attic air sealing checklist
Related pages: Code R-values · Batts and mineral wool · Delivery area · Trade accounts