Guide

Colorado insulation requirements

Front Range attics need R-60 under the 2021 energy code, or R-49 under the 2024 code. Your city decides which one applies (adoption map).

Then see batts, blown-in or spray foam.

R-values by part

Tap a part for the options the code accepts. Board over the studs is continuous insulation.

Tap a part to see the best choice

AtticWallsFloorBasementwallSlabedgeCrawlwall

Code needs · Attic

R-60 or R-49

R-60 under the 2021 code, R-49 under 2024. Spray foam at the roof deck instead has a lower minimum by zone.

Get a Quote
Options, eaves, crawl, sources
  • Source: IECC Table R402.1.3, 2021 and 2024. Basement and crawl walls: R-15ci, R-19 or R-13+5ci. Slab edge: R-10ci.
  • Eave allowance (R402.2.1): the lower attic value needs full-height, uncompressed insulation over the top plate.
  • Wood-frame wall: any one of R-30, R-20+5ci, R-13+10ci or R-20ci. R-20+5ci is R-20 in the cavity plus R-5 of continuous insulation (ci).
  • Floor, 2024: R-30, R-19+7.5ci or R-20ci.
  • Floor, 2024: R-38, R-19+10ci or R-25ci.
  • Floor, 2021: R-30.
  • Floor, 2021: R-38.
  • Blown-in counts at its settled R-value.
  • Unvented attic: fiberglass or cellulose goes under the foam, or rigid board above the deck; the 2024 code lists R-30 board above the deck in zones 5 and 6, R-35 in zone 7.
  • Spray foam on the deck must be a Class II vapor retarder or carry a Class II coating, with no Class I on the ceiling side.
  • Foam alone has no table minimum, so the energy code value governs. Source: IRC R806.5, 2021 and 2024.
  • The data sheet gives the vapor class at your thickness.
  • Crawl walls, 2021: from the floor above down to finished grade, then at least 24 in. more.
  • Crawl walls, 2024: sill plate to the top of the footing. Insulation inside may stop at a floor over 24 in. below outside grade.
  • Exposed earth in a crawl space gets a continuous Class I vapor retarder (2021: unvented crawl spaces only).
  • Floor instead of walls: a vented crawl space or a qualifying unconditioned basement can insulate the floor above (2021 R402.2.8 and R402.2.10; 2024 R402.2.9 and R402.2.11).
  • See the crawl space guide.

Cover the foam

Foam facing the living space needs a thermal barrier: a 15-minute fire cover, such as 1/2 in drywall. A tested coating can replace drywall, but only on the foam it was tested with.

Barriers, paint, programs
  • Barrier alternatives: 23/32 in wood structural panel (IRC) or an NFPA 275 tested material. An attic or crawl space entered only for service takes an ignition barrier, unless the foam passed an approved end-use fire test.
  • Rim joist or sill plate: no thermal barrier at 3-1/4 in or less, 0.5 to 2.0 pcf, flame spread 25 or less, smoke 450 or less.
  • Coating instead of a barrier: only the foam and coating pair tested together. We carry FireShell and No-Burn. FireShell: ICC-ES ESR-3997. No-Burn: IAPMO UES ER-305. Read the current report before you spec.
  • IRC R316.4 to R316.6 (2021), R303.4 to R303.6 (2024); IBC 2603.4 and 2603.9.
  • Latex paint, zone 5: R-5 ci on a 2x4 wall, R-7.5 on a 2x6; or vented cladding over wood structural panels, fiberboard or gypsum.
  • Latex paint, zone 6: R-7.5 ci on a 2x4 wall, R-11.25 on a 2x6; or vented cladding over fiberboard or gypsum.
  • Latex paint, zone 7: R-10 ci on a 2x4 wall, R-15 on a 2x6; vented cladding is not an option.
  • Basement walls and the below-grade part of any wall are exempt. Source: IRC Table R702.7(3), 2021 and 2024.
  • Vented siding (cladding): vinyl, polypropylene or horizontal aluminum siding; brick veneer with a clear airspace; rainscreens (2024 only).
  • Weatherization Assistance Program serves income-qualified households; Energy Smart Colorado offers rebates in mountain counties.

Frequently asked questions

Do 2x6 walls need R-30?

Not if you add R-5 board over the studs. Our 2x6 batts are Knauf Insulation R-21 and ROCKWOOL R23.

Do I have to meet the code when I add insulation to an attic?

Only the part you change must comply. Whether a top-up must meet the full value varies; ask your building department.

Which climate zone is my county in?

Zones go by county, not elevation (IECC Table R301.1). Zone 5B: Adams, Arapahoe, Boulder, Broomfield, Denver, Douglas, El Paso, Gilpin, Jefferson, Larimer, Pueblo, Teller and Weld. Zone 6B: Chaffee and Eagle. Zone 7: Clear Creek, Grand, Lake, Park and Summit.

What is a vapor retarder?

The layer that slows moisture, such as poly or kraft facing. Latex paint needs board over the studs or vented siding. Details are under "Cover the foam".

How far down do basement walls get insulated?

To 10 ft below grade or down to the floor. See the crawl space guide.

Are there insulation incentives?

As of October 2026 the federal credit ended after 2025, and state home rebates closed. Other programs are under "Cover the foam".

Reviewed by the Pop Supply team ·

Sources (32)
  1. Colorado Energy Office, Building energy codes
  2. Colorado Energy Office, Energy codes FAQ
  3. Colorado Energy Office, model code press release (2025-09-02)
  4. Colorado Energy Office, Statewide Building Code Adoption map (2026-08-31)
  5. Jefferson County, Adopted Building Codes
  6. Larimer County, Building Codes
  7. Larimer County, 2024 Building Code Amendments (2026-08-31)
  8. Boulder County, Building Code Amendments 2026
  9. Denver Energy Code 2021, residential efficiency (UpCodes)
  10. 2021 IECC chapter 3, Table R301.1 (UpCodes)
  11. 2024 IECC chapter 3, Table R301.1 (UpCodes)
  12. 2021 IECC chapter 4, R402 envelope (UpCodes)
  13. 2021 IECC chapter 5, existing buildings (UpCodes)
  14. 2024 IECC chapter 4, R402 envelope (UpCodes)
  15. 2024 IECC chapter 5, existing buildings (UpCodes)
  16. 2021 IRC chapter 3, R316 foam plastic (UpCodes)
  17. 2024 IRC chapter 3, R303, Denver text (UpCodes)
  18. 2021 IBC chapter 26, 2603 foam plastic (UpCodes)
  19. 2024 IBC chapter 26, 2603 foam plastic (UpCodes)
  20. 2021 IRC chapter 8, R806.5 unvented attics (UpCodes)
  21. 2024 IRC chapter 8, R806.5, Denver text (UpCodes)
  22. 2021 IRC chapter 7, R702.7 vapor retarders (UpCodes)
  23. 2024 IRC chapter 7, R702.7, Denver text (UpCodes)
  24. ICC-ES ESR-3997, FireShell coatings (2026-07)
  25. IAPMO UES ER-305, No-Burn products (2026-07-07)
  26. Knauf Insulation, EcoBatt wood-frame R-value table
  27. ROCKWOOL, Comfortbatt technical data sheet (2026-07)
  28. IRS, Fact Sheet FS-2025-05, energy credits FAQs (2025-08-21)
  29. IRS, Energy Efficient Home Improvement Credit
  30. Colorado Energy Office, Home Energy Rebate Program (2026-08)
  31. Colorado Energy Office, Weatherization Assistance Program
  32. Energy Smart Colorado, home rebates

Know the R-values your job needs?

Send the job site, wall types and R-values, and we reply with availability and pricing.

Call us:+1 (720) 502-6469

Same-day and next-day delivery on most products across the Front Range. Delivered from Denver.

Request a quote

Tell us what you need and we will reply with availability and pricing.